소아 경골 원위부 골절에서 최소 침습적 잠김 금속판을 이용한 골유합술
- 4예 보고 - |
, , , |
|
Minimally Invasive Percutaneous Plating(Locking Compression Plate) of Distal Tibial
Fractures in Children - 4 cases- |
Ji Won Bak, Sung Jin Shin, Sung Wook Choi, Kyu-Bum Seo |
Correspondence:
Kyu-Bum Seo, |
|
Abstract |
Distal tibia fractures in children are rare and surgical treatments are not well known. Distal tibia fractures with concomitant
fibular fracture are caused by high-energy injury in most cases and it makes surgical treatment difficult due to soft tissue injury
and instability of fracture fragments.
So, we report 4 cases, who were diagnosed as unstable distal tibia fracture, and underwent percutaneous plating by
LCP(locking compression screw), and were followed-up for more than 1 year. |
Key Words:
Tibia, distal fracture, locking compression plate |
|